Changes between Version 1 and Version 2 of cv4400


Ignore:
Timestamp:
2013-09-19T10:30:35-04:00 (12 years ago)
Author:
warb
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • cv4400

    v1 v2  
    5252        </CDRADAR>
    5353
     54}}}
     55
    5456{{{
    5557   <Site
     
    6062            CV4400_SCAN_TIME="4618"
    6163            CV4400_TO_LAN="ENABLED">
    62         </Site>
     64   </Site>
    6365}}}
    6466
    65 }}}
    6667
    6768'''PROTOCOL="ASR9_RADAR"'''
     
    9697send data in conformance with MIL-STD-188.
    9798}}}
     99
     100
     101'''CV4400="ENABLED"'''
     102{{{
     103This adaptation parameter is the main toggle for selecting whether the incoming radar data (for a given
     104radar) is to be processed by the CV4400 filtering/formatting function in ECG. The default for ECG CV4400
     105is DISABLED. If ECG CV4400 filtering is desired, then this parameter must be changed to ENABLED
     106
     107When the ECG CV4400 filter is enabled, additional subparameters must also be set to support the ECG
     108filtering/formatting functionality. The adaptation specialist that is setting up the adaptation for a given site
     109must have access to the configuration data sheet for the short-range radar to be adapted. The data sheet
     110facilitates selection of the appropriate values for CV4400–related parameters within the ECG SCT. Most
     111of the other parameters discussed in subsequent subsections address how data from one message type
     112(i.e., ASR–9) is to be converted for CD2 output (full-scan or skip-scan, depending on adaptation).
     113If CD2 output is not desired, the ECG CV4400 parameter is left DISABLED. The output to
     114HCS/ECG/DARC is whatever the radar site is sending. (Host must receive CD2 skip-scan format data
     115from short-range [ASR] radar).
     116
     117}}}
     118
     119'''CV4400_SKIP_SCAN'''
     120''Note: The example <Site> element does not contain this parameter, so the default will be applied i.e. no skip scan. A sepadapt supporting host (HCS) would need this ENABLED''''''''
     121{{{
     122This parameter is used to enable or disable the ECG CV4400 filter that performs removal of every other
     123scan of incoming radar.
     124The CV4400_SKIP_SCAN parameter is disabled as the default and is set appropriately for the desired
     125output to Host/ECG/DARC. If the CV4400 parameter is enabled and the CV4400_SKIP_SCAN parameter
     126is enabled, then Host/ECG/DARC receives the CD2 skip-scan format data it requires.
     127}}}
     128
     129'''CV4400_TO_LAN="ENABLED"'''
     130{{{
     131This parameter is used to enable or disable the multicasting of radar data after the radar data has been pro-
     132cessed (by) the CV4400 filtering/formatting function in ECG. This parameter should be enabled for ECG/DARC
     133when it is desired to send short-range radar data (that has been processed by the ECG CV4400 con-
     134version software) to the multicast for the DARC and RAPPI clients to receive. The default is DISABLED.
     135}}}